Owon TDS Series Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Owon TDS Series. OWON TDS Series User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - User Manual

TDS Series Touchscreen Digital Storage Oscilloscopes User Manual TDS7104 TDS8104 TDS8204 WWW.OWON.COM.HK

Strany 2 - Branch:

4.Junior User Guidebook 5 4. Junior User Guidebook This chapter deals with the following topics mainly:  Introduction to the structure of the o

Strany 3 - General Warranty

4.Junior User Guidebook 6 Introduction to the Structure of the Oscilloscope When you get a new-type oscilloscope, you should get acquainted with it

Strany 4 - Table of Contents

4.Junior User Guidebook 7 Rear Panel 6543217 Figure 4-2 Rear Panel 1. USB Host port: It is used to transfer data when external USB equipment conne

Strany 5

4.Junior User Guidebook 8 Control (key and knob) Area 87254613 Figure 4-3 Keys Overview 1. G knob (General knob): when a symbol appears in the

Strany 6

4.Junior User Guidebook 9 User Interface Introduction 21345681126272312141720 1822211391015162524197 Figure 4-4 Illustrative Drawing of Display Int

Strany 7 - Safety Symbols

4.Junior User Guidebook 10 11. The pointer shows the trigger level position of the source in trigger menu. 12. The waveform of Math. 13. The wav

Strany 8 - Warning:

4.Junior User Guidebook 11 If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage, do not thro

Strany 9 - 3. General Characteristics

4.Junior User Guidebook 12 Figure 4-5 Auto set Check CH2, CH3 and CH4 by repeating Step 2 and Step 3. How to Implement the Probe Compensation Wh

Strany 10 - 4. Junior User Guidebook

4.Junior User Guidebook 13 Figure 4-7 Adjust Probe How to Set the Probe Attenuation Coefficient The probe has several attenuation coefficients,

Strany 11 - Front Panel

4.Junior User Guidebook 14 How to Use the Probe Safely The safety guard ring around the probe body protects your finger against any electric shock,

Strany 12 - Rear Panel

July 2013 edition V1.0 Copy Right in this Manual © Lilliput Company. All rights Reserved. The Lilliput's products are under t

Strany 13

4.Junior User Guidebook 15 Figure 4-10 Vertical Control Zone 1. Use the button "VERTICAL POSITION" knob to show the signal in the cente

Strany 14

4.Junior User Guidebook 16 through touchscreen" on P18. Introduction to the Horizontal System Shown as Figure 4-11, there are a button and

Strany 15

4.Junior User Guidebook 17 Figure 4-12 Trigger Control Zone 1. Press the "Trigger Menu" button and call out the trigger menu. With the

Strany 16

4.Junior User Guidebook 18 Set the Vertical System through touchscreen Control the vertical position/voltage division of the selected channelSelect

Strany 17

4.Junior User Guidebook 19 Set the Horizontal System through touchscreen Increase the time baseControl the horizontal positionDecrease the time bas

Strany 18

4.Junior User Guidebook 20 Touch to switch between unselected/selected to control the vertical gesture on the left screen Control the vertical positi

Strany 19

4.Junior User Guidebook 21 Control the horizontal position of Zoom WindowControl the horizontal position of Main WindowIncrease the time base of Main

Strany 20

4.Junior User Guidebook 22 window to display the Cursor Measure Menu in the bottom menu.  Set the system time: Touch the time in the top right cor

Strany 21

5.Advanced User Guidebook 23 5. Advanced User Guidebook Up till now, you have already been familiar with the basic operations of the function areas

Strany 22

5.Advanced User Guidebook 24 How to Set the Vertical System The VERTICAL CONTROLS includes 5 menu buttons such as CH1 ~ CH4 and Math, and 8 knobs

Strany 23 - Touch to select the channel

General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years from the date of

Strany 24

5.Advanced User Guidebook 25 below: (1) Press the CH1 button to show channel menu. (2) Select Coupling in the bottom menu. (3) Select DC in th

Strany 25

5.Advanced User Guidebook 26 (1) Press the CH1 button to show channel menu. (2) Select BandWidth in the bottom menu. (3) Select Full in the righ

Strany 26 - Press repeatedly to

5.Advanced User Guidebook 27 Window Rectangle Hanning Hamming Blackman Bartlett Kaiser Select window for FFT. Format Vrms dB Select Vrms for Format

Strany 27 - 4.Junior User Guidebook

5.Advanced User Guidebook 28 2. Select FFT in the bottom menu. 3. Select Source in the right menu; select ① in the left source menu. 4. Sele

Strany 28 - 5. Advanced User Guidebook

5.Advanced User Guidebook 29 Hamming Better solution for magnitude than Rectangle, and good for frequency as well. It has slightly better frequen

Strany 29

5.Advanced User Guidebook 30 aliasing. So pay more attention to the relation between the frequency being sampled and measured. Use VERTICAL POSITION

Strany 30

5.Advanced User Guidebook 31 time base. 2. SEC/DIV knob: it is used to set the horizontal scale factor in the main window or the zoom window. 3.

Strany 31

5.Advanced User Guidebook 32 How to Set the Trigger System Trigger determines when TDS starts to acquire data and display waveform. Once trigger i

Strany 32 - Using FFT function

5.Advanced User Guidebook 33 Coupling AC DC HF LF Block the direct current component. Allow all component pass. Block the high-frequency signal,

Strany 33

5.Advanced User Guidebook 34 The description of the Pulse Width Trigger Menu is as follows: MENU SETTING INSTRUCTION Trigger Mode Pulse Set vertic

Strany 34

i Table of Contents 1. General Safety Requirements ... 1 2. S

Strany 35 - Information of

5.Advanced User Guidebook 35 Slew Rate Slew Rate = (High level - Low level) / Settings Threshold &SlewRate High level Low level Slew Rate Adjust

Strany 36 - Zoom the Waveform

5.Advanced User Guidebook 36 with a frequency lower than 8 kHz.  HF Reject: HF Reject coupling attenuates all signals with a frequency higher than 1

Strany 37 - Trigger Control

5.Advanced User Guidebook 37 Figure 5-2 Peak Detect mode, under which the burrs on the falling edge of the square wave, can be detected and the nois

Strany 38 - 3. Pulse Width Trigger

5.Advanced User Guidebook 38 Figure 5-4 The displayed waveform after the noise is removed under the Average Mode, in which the average number of 16

Strany 39 - 4. Slope Trigger

5.Advanced User Guidebook 39 Press the Acquire button; select Wave Display in the bottom menu, select Type in the right menu. You can switch between

Strany 40 - &SlewRate

5.Advanced User Guidebook 40 3. When the XY Mode is turned on, the reference waveform that has been displayed will be removed from the display autom

Strany 41

5.Advanced User Guidebook 41 To save the current screen image The screen image can be saved to internal/external storage in JPG, BMP or PNG formats.

Strany 42

5.Advanced User Guidebook 42 display/remove reference waveforms" on P42. To save setup files Setup information includes acquisition informatio

Strany 43

5.Advanced User Guidebook 43 3. Select the waveform file in file explorer (*.csv/*.bin), see "To select the path or file in file explorer"

Strany 44 - XY Mode

5.Advanced User Guidebook 44 When entering the interface of editing name, there will be a keypad dialog that let you touch to enter names. The length

Strany 45 - How to Save and Recall

ii To save the current screen image ...

Strany 46

5.Advanced User Guidebook 45 How to Implement the Auxiliary System Function Setting ●Config To change the user interface language 1. Press the Ut

Strany 47 - To save setup files

5.Advanced User Guidebook 46 ●Calibrate Press the Utility button and select Calibrate in the left menu. The description of Calibrate Menu is shown

Strany 48 - To edit file names

5.Advanced User Guidebook 47 The description of Pass/Fail Menu is shown as the follows: Pass/Fail test: Detect whether the input signal is within the

Strany 49 - To manage file

5.Advanced User Guidebook 48 Figure 5-6 Pass/Fail test Note: 1. When Pass/Fail is ON, if you enter XY mode, Pass/Fail will be closed; in the XY mo

Strany 50 - ●Display

5.Advanced User Guidebook 49 How to Measure Automatically Press the Measure button to display the menu for the settings of the Automatic Measureme

Strany 51 - ●Pass/Fail

5.Advanced User Guidebook 50 11. Select PK-PK in the left menu. 12. Select Add in the right menu, the PK-PK added completes, finish setting of CH2.

Strany 52

5.Advanced User Guidebook 51 entire waveform. Vamp: Voltage between Vtop and Vbase of a waveform. Vtop: Voltage of the waveform's flat top,

Strany 53 - ●System

5.Advanced User Guidebook 52 How to Measure with Cursors Press the Cursor button to display the cursor measurement function menu in the bottom menu

Strany 54 - Measure

5.Advanced User Guidebook 53 Figure 5-10 Waveform of Voltage Cursor Measurement Carry out the steps below for the time cursor measurement of the c

Strany 55

5.Advanced User Guidebook 54 Figure 5-11 Waveform of Time Cursor Measurement The Cursor Measurement for FFT mode: Perform the steps below for the

Strany 56 - Fall Time

1.General Safety Requirements 1 1. General Safety Requirements Before any operations, please read the following safety precautions to avoid any pos

Strany 57

5.Advanced User Guidebook 55 Figure 5-12 Wave of Vamp cursor measurement Carry out the steps below for the Frequency cursor measurement: 1. Press

Strany 58

5.Advanced User Guidebook 56 Figure 5-13 Wave of Freq cursor measurement How to Use Autoscale This is a very useful function for first time users

Strany 59

5.Advanced User Guidebook 57 4. Select Wave Period in the bottom menu, select in the right menu, shown as Figure 5-14. Figure 5-14 Autoscale H

Strany 60

5.Advanced User Guidebook 58 Function Items Setting Acquisition Mode Current Vertical Coupling DC Vertical Scale Adjust to the proper division.

Strany 61 - How to Use Autoscale

6.Communication with PC 59 6. Communication with PC TDS series digital storage oscilloscope support communications with a PC through USB or LAN port.

Strany 62 - Autoset

6.Communication with PC 60 Using LAN Port Connect directly (1) Connection. Plug in the LAN line to the LAN port in the rear panel of the oscill

Strany 63

6.Communication with PC 61 Figure 6-3 Set the network parameters of the Software (4) Set the network parameters of the oscilloscope. In the osci

Strany 64 - 6. Communication with PC

6.Communication with PC 62 Figure 6-5 Set the network parameters of the computer (3) Set the network parameters of the Software. Run the software o

Strany 65 - Using LAN Port

6.Communication with PC 63 Utility button, select Config in the left menu. Select Net Config in the bottom menu. Set the IP Address and Port to the s

Strany 66 - Connect through a router

7.Demonstration 64 7. Demonstration Example 1: Measurement a Simple Signal The purpose of this example is to display an unknown signal in the ci

Strany 67

2.Safety Terms and Symbols 2 2. Safety Terms and Symbols Safety Terms Terms in this manual. The following terms may appear in this manual: Warn

Strany 68 - Touch to complete the

7.Demonstration 65 Figure 7-1 Measure Frequency and PK-PK value for a given signal Example 2: Gain of an Amplifier in a Metering Circuit The purpo

Strany 69 - 7. Demonstration

7.Demonstration 66 Gain = Output Signal / Input signal Gain (db) = 20×log (gain) Figure 7-2 Waveform of Gain Measurement Example 3: Capturing a Sing

Strany 70

7.Demonstration 67 through touchscreen" on P18). (10) Check the Trigger State Indicator on the top of the screen, if it is not Ready, push dow

Strany 71

7.Demonstration 68 Example 4: Analyze the Details of a Signal Noise is very common inside most of the electronic signal. To find out what's in

Strany 72

7.Demonstration 69 User would see a much reduced random noise level and make it easy to see more details of the signal itself. After applying Average

Strany 73

7.Demonstration 70 (7) Switch XY Mode as ON. The oscilloscope will display the input and terminal characteristics of the network in the Lissajous

Strany 74

7.Demonstration 71 Example 6: Video Signal Trigger Observe the video circuit of a television, apply the video trigger and obtain the stable video o

Strany 75

8.Troubleshooting 72 8. Troubleshooting 1. Oscilloscope is powered on but no Display.  Check whether the power connection is connected properl

Strany 76

9.Technical Specifications 73 9. Technical Specifications Unless otherwise specified, the technical specifications applied are for TDS series only

Strany 77 - 8. Troubleshooting

9.Technical Specifications 74 Performance Characteristics Instruction Time delay between channel(typical) 150ps Horizontal System Sampling rate range

Strany 78

2.Safety Terms and Symbols 3 To avoid body damage and prevent product and connected equipment damage, carefully read the following safety information

Strany 79

9.Technical Specifications 75 Performance Characteristics Instruction Measurement Cursor △V and △T between cursors Automatic PK-PK, Max, Min, Vtop, V

Strany 80

9.Technical Specifications 76 General Technical Specifications Display Display Type 8" touchscreen color LCD Display Resolution 800 (Horizon

Strany 81

10.Appendix 77 10. Appendix Appendix A: Enclosure Standard Accessories:  4 Passive probes: 1.2 m, 1:1 (10:1)  1x CD (PC link application

Strany 82 - 10. Appendix

3.General Characteristics 4 3. General Characteristics  Max 200MHz bandwidth, up to 2GS/s realtime sample rate  7.6M record length  Waveform

Komentáře k této Příručce

Žádné komentáře